Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiology ; (12): 582-585, 2015.
Article in Chinese | WPRIM | ID: wpr-476580

ABSTRACT

Objective To compare the differences of the spectral CT parameters between benign and malignant mediastina lymph nodes and to investigate the value of spectral imaging in the differential diagnosis. Methods According to the follow-up and pathology results, a total of 73 patients were enrolled in this study. One experienced radiologist determined the locations of lymph nodes on CT images corresponding to the surgical pathological ones. A total of 47 malignant nodes and 65 benign nodes were found. The longest and shortest diameters of lymph nodes in mediastina window were measured .The vHU, IC, WC, Zef and the CT values of normal lung, normal muscle and lymph nodes at 40, 70 and 140 keV were measured. The indices were compared between the benign nodes and malignant nodes by independent-samples t test. The Spectral HU curves were drawn. Results The long and short diameter of malignant lymph nodes were (28.8 ± 10.5),(20.3 ± 9.1)cm , while they were were (14.0 ± 4.6),(7.5 ± 1.8)cm for benign lymph nodes. Malignant nodes were significantly larger than benign nodes (t= 6.54, 7.13, respectively, P0.05). The two groups showed similar spectral HU curve slopes (1.86 values 1.73). Conclusion Spectral imaging may not be helpful in the differential diagnosis of malignant and benign lymph nodes.